The Dell™ PowerVault™ ML6000 tape library supports Quantum intelligent libraries support Intelligent libraries support both a media changer device (device type 08h) and, depending on the library model and configuration, a controller device (device type 0Ch). The controller device is used primarily to aid initialization and discovery for the servers in conjunction with the library’s Logical Library model. Only the Scalar i2000/i6000 and Scalar i500 library models support controller device (DA blade) configurations. Library models without DA blades configure tape drives to host the library control path to the logical library partition and hereby provide access to the media changer devices.

Note: “DA blade” is a generic term used in this manual to describe a Fibre Channel (FC)-to-FC I/O blade. The DA blade controller device is not a pure controller device, in that it does not support all the mandatory commands defined by SCC. This is an accepted industry practice established by vendors of bridges and routers.

This device model approach works by having the controller device or tape drive (typically at LUN 0) respond to commands directed at LUN 0, including the REPORT LUNS command, and the media changer device(s) (one media changer device per logical library partition) typically respond to commands on LUN1. This approach allows an initiator (host) to issue a REPORT LUNS command to the controller device to retrieve a listing of all available logical units, to determine the presence of connected Data Transfer Device(s) and media changer device(s).

ClosedDA Blade Controller Device Commands and Parameters

The following table lists the commands supported by the DA blade controller device.

Table 1: DA Blade Controller Device Supported Commands

Command

Code

INQUIRY

12h

MODE SELECT (6)

15h

MODE SELECT (10)

55h

MODE SENSE (6)

1Ah

MODE SENSE (10)

5Ah

READ BUFFER

3Ch

REPORT LUNS

A0h

REQUEST SENSE

03h

TEST UNIT READY

00h

WRITE BUFFER

3Bh

The following table lists the parameters supported by the DA blade controller device.

Table 2: DA Blade Controller Device Supported Parameters

Command

Page

Code

Inquiry

Supported VPD Pages

00h

Inquiry

Unit Serial Number Page

80h

Inquiry

Device Identification Page

83h

Mode Select/Sense

Disconnect Reconnect Page

02h

Mode Select/Sense

FC LU Control Page

18h

Mode Select/Sense

FC Port Control Page

19h

Mode Sense

Return all pages

3Fh

ClosedMedia Changer Commands and Parameters

The following table lists the commands supported by the media changer device.

Table 3: Media Changer Supported Commands

Command

Code

Exchange Medium - A6h⁴ A6h

Initialize Element Status - 07h

07h

Initialize Element Status With Range - E7h/37h

E7h

Inquiry - 12h¹

12h

Log Sense - 4Dh

4Dh

Mode Select (6) - 15h

15h

Mode Select (10) - 55h

55h

Mode Sense (6) - 1Ah

1Ah

Mode Sense (10) - 5Ah

5Ah

Move Medium - A5h

A5h

Persistent Reserve In - 5Eh¹

5Eh

Persistent Reserve Out - 5Fh¹

5Fh

Position to Element - 2Bh

2Bh

Prevent Allow Medium Removal - 1Eh

1Eh

Read Buffer - 3Ch¹

3Ch

Read Element Status - B8h

B8h

Release Element (6) - 17h¹

17h

Release Element (10) - 57h¹

57h

Report Element Information - 9Eh⁵ 9Eh

Report LUNS - A0h²

A0h

Request Sense - 03h¹

03h

Request Volume Element Address - B5h³

B5h

Reserve Element (6) - 16h¹

16h

Reserve Element (10) - 56h¹

56h

Send Diagnostic - 1Dh

1Dh

Send Volume Tag - B6h³

B6h

Test Unit Ready - 00h¹

00h

Write Buffer - 3Bh¹

3Bh

1. If the library control path is configured via a tape drive, this command is processed by the tape drive on behalf of the media changer device.

2. This command is supported by a controller device or tape drive hosting a media changer device.

3. Supported only by Scalar i2000 and Scalar i6000.

4. Supported only by Scalar i7 RAPTOR

5. Supported only by Scalar i3/i6/i6H and Scalar i7 RAPTOR.

The following table lists the parameters supported by the media changer device. The media changer device does not support any diagnostic parameters.

Table 4: Media Changer Supported Parameters

Command

Page

Code

SubPage Code

Inquiry

Supported Vital Product Data Page (00h)

00h

00h

Inquiry

 Unit Serial Number Page (80h)

80h

00h

Inquiry

Device Identification Page (83h)

83h

00h

Inquiry

Management Network Addresses Page (85h)

85h

00h

Inquiry

Vendor Specific Device Capabilities Page (C8h)

C8h

00h

Inquiry

Firmware Revision Page

C0h

 

Inquiry

Vendor Specific Page

D0h

 

Inquiry

Implemented SCSI-2 Command Page

E0h

 

Inquiry

Implemented Vendor Specific Page

E1h

 

Inquiry

Failover Key Page

FFh

 

Log Sense

Supported Log Page (00h)

00h

00h
Log Sense

Temperature Log Page (0Dh)²

0Dh 00h
Log Sense

Temperature Log Parameter Field Description (see Table 5).

Tape Alert Response Log Page (12h)²

12h 00h

Log Sense

Tape Alert Response Log Parameter Field Description (see Table 6).

Tape Alert Log Page (2Eh)

2Eh

00h
Log Sense Humidity Log Page (30h)² 30h 00h

Mode Sense

Disconnect-Reconnect Page (02h)¹

02h

00h

Mode Sense

Fibre Channel Logical Unit Control Page (18h)¹

18h

00h

Mode Sense

Fibre Channel Port Control Page (19h)¹

19h

00h

Mode Sense

Informational Exceptions Control Page (1Ch)

1Ch

00h

Mode Sense

Element Address Assignment Page (1Dh)

1Dh

00h

Mode Sense

Transport Geometry Parameters Page (1Eh)

1Eh

00h

Mode Sense

Device Capabilities Page (1Fh)²

1Fh

41h
Mode Sense Extended Device Capabilities Mode Page (1Fh/41h) 1Fh 00h

Mode Sense

All Mode Pages (3Fh/00h)

3Fh

00h
Mode Sense

Specific SubPage Mode Pages (xxh/FFh)

(reporting subpages in the page_0 format for subpage 00h and in the sub_page format for subpages 01h – FEh)²

00h - 3fh FFh
Mode Sense

All SubPage Mode Pages (3Fh/FFh)

(reporting subpages in the page_0 format for subpage 00h and in the sub_page format for subpages 01h – FEh)²

3fH FFh

1. If the library control path is provided by a tape drive, this page is provided by the tape drive.

2. Supported by the Scalar i7 RAPTOR only

 

Table 5: Temperature Log Parameter Field Description

Parameter Code DU TSD ETC TMC Formant and Linking Parameter Length
0000h 0 0 0 00b 00b 2

Table 6: Tape Alert Response Log Parameter Field Description

Parameter Code DU TSD ETC TMC Formant and Linking Parameter Length
0000h 0 1 0 00b 00b 08h
ClosedGeneral Command Support Behavior
ClosedMultiple Initiator Support

Multiple initiators are not supported on the parallel SCSI or SAS interfaces. Information such as Unit Attentions and SCSI sense data will be held for only a single initiator. Multiple initiators are supported on the Fibre Channel interface. Unit attentions and SCSI sense data will be held for each initiator.

ClosedElement Type Codes
Code Element Type Definition
0000b (0) All element types
0001b (1) Medium transport element (accessor)
0010b (2) Storage element
0011b (3) Import/Export element
0100b (4) Data transfer element (drives)
ClosedElement Addressing

The element-addressing model follows that of previous Quantum libraries. The starting addresses of the four element types are:

  • 0001h: Medium Transport.

    Note: Depending on product model , one or two physical media changers (robots) may be installed, but only a single media changer device will be virtualized and reported.

  • 0010h: Import/Export
  • 0100h: Data Transfer
  • 1000h: Storage
ClosedCommand Status

Individual command status responses are not documented, as they all follow the same general format as described here. After processing any command, the library returns status from among the following:

Status Description
Good

The library returns a Good status (00h) when it is able to process the command without errors.

Busy

The library returns Busy status (08h) when a motion command is still being processed, or the library is generally not able to process additional commands at that time.

Reservation Conflict

The library returns a Reservation Conflict (18h) whenever an initiator attempts to access a logical unit that has been reserved by another initiator, except for the following commands:

  • INQUIRY
  • LOG SENSE
  • MODE SENSE (only if the library control path is configured through a tape drive)
  • PREVENT/ALLOW MEDIUM REMOVAL
  • READ ELEMENT STATUS (only when the Current Data [CurData] field is set to 1)
  • REPORT ELEMENT INFORMATION
  • REPORT LUNS
  • REQUEST SENSE
  • TEST UNIT READY
Check Condition

The library returns the Check Condition status (02h) when the following general situations occur (all generate sense data):

  • The library is Not Ready (sense key 02h)
  • The library has encountered a Hardware Error (sense key 04h)
  • A parameter in the CDB is invalid or there is an invalid field in a parameter list, resulting in an Illegal Request (sense key 05h)
  • A Unit Attention condition is pending (sense key 06h)
  • A command has been aborted (sense key 0Bh)

For a complete list of all possible sense data and their causes, refer to Request Sense - 03h. This status information will not be separated by individual commands.

Status values of Condition Met, Intermediate Condition Met, and Queue Full are not currently used. The Initiator should issue a Request Sense command to determine the precise cause of the Check Condition status and clear it.

Response data, however, will be documented as applicable for each command, and included as part of the command section.

ClosedUnit Attentions

Unit Attentions will be queued by the library as necessary to report all events and conditions. They are presented in the order of their occurrence (first in, first out). Unit attentions are generated for the following conditions:

  • A power on or a reset (external or internal) occurred
  • A library door closed, or a transition from not ready to ready occurred
  • An import/export station or magazine closed
  • An element status change for storage, data transfer or I/E elements.
  • A firmware update completed
  • A persistent reservation has been preempted or released, or a registration has been preempted
  • Mode parameters have changed
ClosedResets

Either a Power On Reset or a SCSI Reset resets the library. When reset, the library does the following:

  • Clears all non-persistent reservations
  • Clears Prevent/Allow Medium Removal settings
ClosedCommon CDB Fields

Each Command Descriptor Block contains a Logical Unit Number (LUN) field as well as a Control byte field. The LUN field is bits 5-7 of byte 1 and is there only for legacy compatibility. Logical Unit selection should be accomplished via the Identify message.

The Control byte is shown in the following table. It is always the last byte of a CDB, regardless of the size of the CDB.

Table 7: Control Byte

Bit

Byte

7

6

5

4

3

2

1

0

last

Vendor Specific

Reserved

NACA

Flag

Link

Field Description
Vendor Specific

This field is used to provide additional data or control for a command. Specific uses (if any) are described within the applicable commands.

Normal Auto Contingent Allegiance (NACA)

If this field is set to 0, the initiator should issue a REQUEST SENSE command immediately following receipt of a Check Condition. If this field is set to 1, ACA support will be provided.

Flag

This field is not supported and must be set to 0.

Link

This field is not supported and must be set to 0.

ClosedReserved Fields

Reserved fields are not checked, and no error will be sent if they contain non-zero values.

ClosedVendor Specific Fields

Vendor Specific fields are not checked and no error will be sent if they contain non-zero values, unless specific uses are defined within a SCSI command and vendor specific settings are required.

ClosedOnline/Offline Operation

Each media changer device can be placed in either an online or offline mode. The purpose of these modes is to configure whether the media changer device is being controlled by a SCSI initiator or by the local or remote user interface. When the media changer device is online, a SCSI initiator is controlling it and all SCSI commands are supported. When the media changer device is offline, the local or remote user interface is controlling it, and the only allowed SCSI commands are

  • INQUIRY
  • REPORT LUNS
  • REQUEST SENSE
  • TEST UNIT READY
  • MODE SENSE
  • READ ELEMENT STATUS. The command is allowed with DVCID=1, VOLTAG=0 while the library is offline.

All other commands will respond with a check condition, along with an ASC/ASCQ of 04/8Dh (Logical unit offline) or 04/12h (Logical unit not ready, offline).

Note: If the SCSI media changer device is configured via a library control path-enabled tape drive, RESERVE and RELEASE commands are also accepted and handled when the library is reporting offline status.

The DA blade controller device SCSI command set is not affected by the online/offline mode of the media changer device.

ClosedSupported Interfaces

The library supports SAS and Fibre Channel interface types.

ClosedFibre Channel Interface Support

Fibre Channel connections support configurations for Point-To-Point and Loop topologies. While tape drives support Point-To-Point (N), Loop (L) as well as preferred connections for Point-To-Point Preferred (NL) and Loop Preferred (LN), DA blade configurations support selections for Class 3 Loop-Preferred connections only. Private arbitrated loops are supported by DA blades if the library is not attached to a Fibre Channel fabric, and public arbitrated loops are supported if the library is attached to a Fibre Channel fabric.

ClosedSAS Interface Support

SAS interface connections support direct connections. Configuration options do not exist.

ClosedLogical Libraries

The underlying physical library is not exposed externally to applications. Rather, logical representations of media changer devices are created, and these are presented instead.Rather, logical representations of one to 18 media changer devices are created, and these are presented instead. Through this method the physical library can be partitioned and concurrently shared in a heterogeneous environment. Depending on library model and number of configured drives, 1 to 18 partitions can be created. Storage and Data Transfer elements cannot be shared across logical libraries; they can only be assigned to one logical library at a time. The Medium Transport element (the robotic mechanism) is shared across all logical libraries, and as a result there may be some delays encountered as each logical library waits its turn for this shared resource.

Depending on library model, Import/Export elements can also be shared across logical libraries. This is further discussed in Mailbox Behavior. All other aspects of the logical media changer devices are identical to an independent physical media changer device.

ClosedMailbox Behavior

The following characteristics affect Import/Export elements:

  • The Import/Export elements are contained in removable magazines. When the magazines are removed, the elements are still counted in the number of Import/Export elements and will have element descriptors returned for them in response to a READ ELEMENT STATUS command. Their element status will indicate that they are not accessible, and will also report an exception with an ASC/ASCQ of 3B/12.
  • Some libraries are configured with multiple physical mailboxes, each containing their own set of magazines. Whenever a mailbox is opened, the status for the elements it contains will indicate that they are not accessible until the mailbox is closed again.
  • The Import/Export magazines can be assigned to and shared by different logical libraries. The Import/Export elements they contain are then used on a “first come, first served” basis. When shared Import/Export elements are in use by one logical library, element status for those elements will indicate that they are full, but not accessible for all other logical libraries that share them. The presence of media and associated volume tag information will only be available to the logical library using the elements at that time. When media is removed from the shared elements, they become available for use by any logical library requesting them, and their element status indicates that they are accessible.

These characteristics require applications to process the complete element status returned in the element descriptors (including accessibility and exception conditions) to achieve optimum usage of the Import/Export elements. Reliance on only full or empty element status may result in failed operations (e.g., an Export). This might be due to not locating a usable Import/Export element when several may actually be available, if the search had only taken into account full or empty status rather than accessibility.

ClosedDrive Cleaning

The library always evaluates drive cleaning needs after unloading data cartridges. If a drive cleaning need is determined, the library will report, suppress, or perform cleaning options depending on configured partition cleaning policy.

The library supports the following three partition cleaning policies:

Manual Cleaning (Default)

This option indicates that the library or application will not automatically initiate cleaning. You will receive drive status and/or RAS ticket notification that cleaning is needed.

Application-Managed Cleaning

This option allows you to let a third party application determine when drives need to be cleaned. RAS tickets to indicate drive cleaning needs will not be generated by the library.

Library-Initiated Automatic Cleaning

This option allows you to have the library determine and perform drive cleaning when drives need to be cleaned. You must have cleaning slots defined and cleaning media imported to use this feature.

While a cleaning operation is in progress, the Move Medium command will not occur until the cleaning operation completes. Cleaning operations vary by drive and conditions, but can take up to a few minutes to complete.

Element status for the Data Transfer element being cleaned will not reflect the presence of the cleaning cartridge. It will continue to report that it is empty and accessible.

 

ClosedRemoved Drives

Depending on how the library is configured, occasionally Data Transfer elements will be reported where no drive is physically present at the time. This could be due to a drive that has been removed for service, or simply a placeholder for the addition of a future drive. These empty “drive bays” will be counted and reported via Mode Sense and Read Element Status commands. These elements could appear in between Data Transfer elements that are present, creating “gaps” among the physical drives. This should not be considered an error. Thus, removed drives will be reported in READ ELEMENT STATUS data with an ACCESS bit set to zero and an EXCEPT bit set to one with a vendor specific ASC/ASCQ of 83/04h, DATA TRANSFER ELEMENT NOT INSTALLED, or ASC/ASCQ 3B/1Ah, DATA TRANSFER DEVICE REMOVED.

6-69028-01   | Initial publication date: Monday, February 28th, 2022 | Last updated on Tuesday, June 30, 2026.